Energy savings case study 10-story Commercial Office Building – East Florida
  • 450 Ton Cooling Capacity - CHW VAV System
  • 1,000,000 BTU Heating Capacity - Hydronic Heating System
    • Installed Complete Building Automation System
    • Installed Distech LonWorks Open Protocol Controllers
    • Installed Inet Web Based Graphical User Interface
    • Installed Inet Web Based Tennant Override/Billing System
    • Installed New 450 Ton SMARDT/Turbocor Chiller
    • Installed New Cooling Towers
    • Installed 4ea New 250,000 BTU Boilers
    • Installed VFDs on all Pumps and Fans
    • Converted all Mechanical Systems to Demand Based Variable Flow
    • Implemented Demand Based Optimization Energy Management Strategies
    • Reduced Total Energy Consumption by 43%
Energy savings case study Aircraft Service Facility – Orlando FL
  • 200 Ton Air Cooled DX - Temperature, Humidity, Flow & Pressure Control
    • Installed Complete Process Control System for Aircraft Paint Booths
    • Installed Distech BACnet Open Protocol Controllers
    • Installed Niagara AX Web Based Graphical User Interface
    • Installed Touch Screen Panel PC for Local User Interface
    • Dramatically Improved System Performance
    • Reduced Total Energy Consumption
Energy savings case study Executive Airport - Central Florida
  • 50 Ton Cooling Capacity – Air-Cooled DX VAV System
    • Installed Complete Building Automation System (HVAC & Lighting)
    • Installed Distech LonWorks Open Protocol Controllers
    • Installed Niagara AX Web Based Graphical User Interface
    • Installed New 50 Ton Condenser
    • Installed New 50 Ton Evaporator Coil
    • Implemented Demand Based Optimization Energy Management Strategies
    • Reduced Total Energy Consumption by 26% (24/7 Operation)
Energy savings case study Elementary School - Central Florida
  • 220 Ton Cooling Capacity – Air-Cooled DX Under Floor VAV System
    • Installed Complete Building Automation System
    • Installed Distech LonWorks Open Protocol Controllers
    • Installed Niagara AX Web Based Graphical User Interface
    • Implemented Demand Based Optimization Energy Management Strategies
    • Reduced Total Energy Consumption by 34%
Energy savings case study 3-story Commercial Office Building - Central Florida
  • 70 Ton Cooling Capacity – Water Cooled DX VAV System
  • 1000 Ton Condenser Water Plant – Supplies Condenser Water to Several Surrounding Buildings
    • Installed Complete Building Automation System
    • Installed Distech LonWorks Open Protocol Controllers
    • Installed Niagara AX Web Based Graphical User Interface
    • Implemented Demand Based Optimization Energy Management Strategies
    • Reduced Total Energy Consumption by 44%
Energy savings case study 3-story Commercial Office Building - Central Florida
  • 140 Ton Cooling Capacity – Water Cooled DX VAV System
  • 750 Ton Condenser Water Plant – Supplies Condenser Water to Several Surrounding Buildings
    • Installed Complete Building Automation System
    • Installed Distech LonWorks Open Protocol Controllers
    • Installed Niagara AX Web Based Graphical User Interface
    • Implemented Demand Based Optimization Energy Management Strategies
    • Reduced Total Energy Consumption by 38%
Energy savings case study 3-story Commercial Office Building – East Florida
  • 120 Ton Cooling Capacity – Air-Cooled DX VAV System
    • Upgrade Existing Building Automation System
    • Installed Niagara AX Web Based Graphical User Interface
    • Integrated to Existing Honeywell Controllers (Lonworks)
    • Installed Distech & Honeywell LonWorks Open Protocol Controllers
    • Implemented Demand Based Optimization Energy Management Strategies
    • Reduced Total Energy Consumption
Energy savings case study Retail Shopping Mall – East Florida
  • 1750 Ton Cooling Capacity - CHW CV System
    • Installed Complete Building Automation System (HVAC & Lighting)
    • Installed Distech LonWorks Open Protocol Controllers
    • Installed Niagara AX Web Based Graphical User Interface
    • Integrated to Existing Trane Centrifugal Chiller (BACnet)
    • Integrated to Existing York Centrifugal Chillers (JCI N2)
    • Integrated to Existing Onicon BTU Meters (JCI N2)
    • Installed 3ea New 600 Ton Cooling Towers (1800 Tons)
    • Implemented Demand Based Optimization Energy Management Strategies
    • Reduced Total Energy Consumption by 25%
Energy savings case study Large Campus Church - Central Florida
  • 750 Ton Cooling Capacity – OUC - CHW VAV System
    • Upgrade Existing Building Automation System
    • Completed Niagara AX Installation and Database Programming After Previous Controls Contractor Failed to Perform Integration
    • Programmed Niagara AX Web Based Graphical User Interface
    • Integrated to Existing Invensys Controllers (Lonworks)
    • Installed Distech LonWorks Open Protocol Controllers
    • Implemented Demand Based Optimization Energy Management Strategies
    • Reduced Total Chilled Water Utility Usage & Eliminated Low Delta Penalty
Energy savings case study Major Theme Park - Central Florida
  • Integration Service & Consulting (Process and HVAC Control)
    • Integrated to Existing Delta Controllers (BACnet)
    • Integrated to Existing ABB VFDs (BACnet)
    • Installed Distech BACnet Open Protocol Controllers
    • Installed Niagara AX Web Based Graphical User Interface
    • BACnet Integration
    • MODbus Integration
    • Trane Legacy Protocol Integration
Energy savings case study 90,000 sq-ft Commercial Office Building – West Florida
  • Air-Cooled DX CV System
    • Upgrade Existing Building Automation System
    • Installed Niagara AX Web Based Graphical User Interface
    • Integrated to Existing Johnson Controllers (JCI N2)
    • Installed Distech LonWorks Open Protocol Controllers
    • Implemented Energy Management Strategies
    • Reduced Total Energy Consumption
Energy savings case study Condominium – East Florida
  • Water Cooled DX CV System
    • Installed Condenser Water Plant Automation System
    • Installed Distech LonWorks Open Protocol Controllers
    • Installed Niagara AX Web Based Graphical User Interface
    • Integrated to ITT Variable Frequency Drives (MODbus)
    • Implemented Demand Based Optimization Energy Management Strategies
    • Reduced Total Energy Consumption
Energy savings case study Meeting and Performance Venue - Central Florida
  • Air Cooled DX CV System
    • Installed Complete Building Automation System
    • Installed Distech LonWorks Open Protocol Controllers
    • Installed Honeywell LonWorks Open Protocol Controllers
    • Installed Niagara AX Web Based Graphical User Interface
    • Implemented Demand Based Optimization Energy Management Strategies
    • Reduced Total Energy Consumption